Summary: pressure relief, check and pressure-reducing valves serve different purposes. A relief valve discharges water to control overpressure; a check valve opposes reverse flow; a pressure-reducing valve controls downstream pressure. They can work together, but their selection and location depend on how the piping system behaves. Before buying, check pressures, flow rates and what happens when pumps and irrigation zones start or stop operating.
Why these three valves are often confused
All three may be installed between the pumping equipment and the irrigation zones, but one does not automatically replace another. A pressure-reducing valve should not be treated as complete protection against water hammer; a check valve does not discharge excess pressure; and a relief valve does not keep a pump primed.
Start with the observed symptoms: pipe failures when the pump stops, reverse flow through the discharge line, or emitters operating outside the pressure range specified in their catalog. These signs guide the investigation, but do not identify the cause on their own. The problem may involve more than one device or the sizing of the piping system itself.
Pressure relief valve: discharges water to control excess pressure
A relief valve provides an outlet for water when pressure exceeds its setting. For example, the product sheet for the BERMAD 73Q, from the Waterworks range, describes a rapid response to rising pressure and gradual closing. Protection depends on discharge capacity, valve response and the installation specified in the design.
A quick pressure relief valve is not the same as a surge-anticipating valve. The BERMAD 735-M surge-anticipating valve responds to the initial pressure drop associated with a sudden pump stop, opening before the returning pressure wave arrives. The 73Q responds to high water pressure. Specifying a relief valve alone therefore does not establish that the piping system is protected during every shutdown.
Where to assess installation: on a branch of the piping system, with discharge provisioned and routed to a suitable destination. The location is not simply a matter of placing it near the pump: it depends on vulnerable points and transient analysis. The connection and outlet must allow the calculated discharge without creating new risks at the site.
What to consider: normal and maximum operating pressures, the allowable pressure limits of the components, discharge flow rate and piping conditions. The setting should not be chosen merely to stop the valve from opening; it must provide the protection specified in the design. An undersized valve or restricted discharge path may fail to control the pressure peak.
Pressure can also fall during a transient. This phase requires separate analysis, as explained in water hammer in irrigation. Air admission and release are discussed in the article on the air valve.
Check valve: prevents water from flowing back
A check valve allows flow in the intended direction and closes to restrict reverse flow. Its sealing performance, head loss and closing response vary with the model and operating conditions.
Typical installation locations:
- On the pump discharge: to prevent reverse flow through a stopped pump. In a multiple-pump installation, a check valve on each pump can prevent one unit from receiving flow from the others.
- At the end of the suction line, as a foot valve: in certain arrangements, it helps retain the water needed to keep the pump primed. It does not replace initial priming, and its application differs between pump types.
- In systems that inject chemicals: a check valve can form part of backflow prevention. Protecting the water source depends on the combination of devices, siphoning conditions and injection operation; a single check valve does not establish that the source is protected.
University of Minnesota Extension describes a combination of measures to prevent backflow and siphoning during chemigation. This is an external technical reference with requirements specific to that location, not installation instructions or legislation applicable to Brazil. For your site, the design must specify the protection and check the applicable requirements.
What to consider: flow direction, permitted installation orientation, material compatibility, head loss and closing dynamics. A technical article by Bruce Fenwick in Valve Magazine shows that closing after reverse flow has begun can cause water hammer and damage equipment. A check valve should not be selected solely by its connection diameter.
The head loss introduced by the valve contributes to the required pump head. See the article on how to choose the pump for irrigation.
Pressure-reducing valve: stabilizes downstream pressure
A pressure-reducing valve controls an outlet pressure below the available inlet pressure, within the pressure and flow ranges for which it was selected. The BERMAD 720 Waterworks is an example of a hydraulically operated pressure-reducing valve; its product sheet requires inlet pressure, outlet pressure and flow-rate data for sizing and cavitation assessment.
For irrigation, distinguish between two applications:
- Pilot-operated pressure-reducing valve: used at control stations or irrigation zones, according to the capacity and application of the model.
- Emitter pressure regulator: usually compact and with a specified pressure rating, selected for the flow-rate range of the sprinklers or lines it serves.
These devices do not necessarily behave the same under no-flow conditions. Hunter’s guide distinguishes conventional regulators, which need flow to regulate, from models with a pressure-limiting function under no-flow conditions. Do not assume that every regulator maintains its rated outlet pressure when a downstream shut-off valve closes.
Why use pressure control: elevation differences, changes in which irrigation zones are operating, and variations in the water supply can alter emitter pressure. Pressure control helps keep emitters within the operating range specified by the manufacturer.
A common source of mistakes: the device only reduces pressure; it cannot increase it. Inlet pressure must be sufficiently above the desired outlet pressure, and flow must stay within the specified range. The required pressure differential is model-specific, not a universal value for irrigation. If inlet pressure is insufficient, investigate pumping, filters, head losses and piping conditions before selecting a pressure-reducing valve.
The pressure-compensating drippers also have a specified operating pressure range. They can be part of the solution, but do not remove the need to check the hydraulics of the irrigation zone.
Quick comparison
| Pressure relief valve | Check valve | Pressure-reducing valve | |
|---|---|---|---|
| Main function | Discharge water to control overpressure | Restrict reverse flow | Control a lower downstream pressure |
| How it works | Opens a discharge path according to its setting and operating characteristics | Closes to oppose flow reversal | Modulates water flow |
| Installation location to assess | Branch connection with a sized discharge path | Pump discharge, suction line or injection assembly, depending on the device | Control station, irrigation zone or emitter, depending on the model |
| Key selection factors | Setting, response and discharge capacity | Sealing performance, head loss and closing behavior | Pressures, flow rate and operating pressure differential |
| Important limit | Does not address every phase of a transient on its own | Does not discharge excess pressure or guarantee protection against contamination on its own | Cannot increase pressure and may not control pressure under no-flow conditions |
Common mistakes
- Relying only on a pressure-reducing valve for water hammer protection. Protection against transients requires specific analysis, not just control of pressure during normal operation.
- Changing the relief valve setting without checking the system. Frequent opening may indicate an unsuitable setting or a real pressure problem.
- Installing a check valve against the flow direction or in an unapproved orientation. Check the model’s manual, including whether it is suitable for suction-side or discharge-side installation.
- Ignoring water quality and protection of the pilot circuit. Filtration must meet the requirements of the equipment and emitters. No single mesh size applies to every pilot-operated valve; see the selection criteria for irrigation filters.
- Failing to check inlet and outlet pressures. Measurement points help verify operation; assessing rapid pressure peaks may require dedicated instrumentation and analysis.
- Treating maintenance as optional. A 2004 assessment by Embrapa Hortaliças documented surge protection devices and deteriorated foot valves. For the center-pivot system at that site, water quality justified annual cleaning of the regulators. This is a historical example, not a mandatory maintenance interval for every installation. Follow the manufacturer’s guidance and the conditions of use.
What to measure before deciding
- Static and operating pressures: at the pump discharge, at the irrigation headworks and in critical zones, considering different operating combinations.
- Elevation differences and component limits: pressure ratings of pipes, fittings and equipment, together with piping lengths and diameters.
- Flow rates and emitter requirements: irrigation-zone demand and operating pressure range.
- Pump starts, pump stops and valve closures: how pumps and valves operate, including during power failures. A variable-frequency drive or soft starter alone does not establish protection against transients.
- Chemical injection: injection layout, the possibility of backflow or siphoning, and the specified protective devices.
Calculating head losses in irrigation helps assess pressure during operation. Transient analysis addresses rapid changes separately. Together, this information guides device selection and review of the piping system.
FAQ
Can I use a check valve instead of a pressure relief valve? No. A check valve controls flow direction, while a relief valve discharges water to control overpressure. Closing of the check valve itself must also be considered in water hammer analysis.
Do I need a check valve for fertigation? Backflow prevention must be part of the system assessment. Check valves may form part of the solution, but siphoning, injection shutdown and protection of the water source must also be assessed. The number and types of devices depend on the design and applicable requirements, not a generic rule taken from another country.
Conclusion
Pressure relief, check and pressure-reducing valves have different roles and can complement one another. Selection starts with data about the piping system and how it operates, before comparing models or prices.
If you have pipe failures, reverse flow or irregular pressure, Perin Irrigação can assess the system and define the scope of a project. Explore our solutions for automation and fertigation. To start the conversation, send your municipality, crop, approximate area and water source via WhatsApp (14) 99824-5219.
Email: contato@perinirrigacao.com.br.
Sources consulted (accessed on 14 November 2026)
- BERMAD. Model 73Q – Quick Pressure Relief Valve (Waterworks range, product sheet in Portuguese).
- BERMAD. 735-M – Surge-Anticipating Control Valve.
- BERMAD. Model 720 – Pressure-Reducing Valve (Waterworks, product sheet in Portuguese).
- HUNTER INDUSTRIES. Guide to irrigation pressure regulation.
- UNIVERSITY OF MINNESOTA EXTENSION. Chemigation safety measures.
- FENWICK, B. Water hammer—check it out. Valve Magazine, 15 April 2008.
- SILVA, H. R. da et al. Diagnosis of the irrigation system and hydraulic and civil structures of the experimental fields sector of the National Vegetable Research Center. Brasília: Embrapa Hortaliças, 2004 (Documents, 66).